Table. I – IP Code – Ingress Protection of Solid objects

Short Description & IP Code Application Tips

0 = Not Protected

IP1X = Protected against ingress of solid objects of Ø 50 mm and bigger – Use Handled Sphere Probe

IP2X = Protected against ingress of solid objects Ø 12 mm and bigger – Use Jointed Finger Probe

IP3X = Protected against ingress of solid objects Ø 2,5 mm and bigger – Use Rode Wire Probe Ø 2,5 mm

IP4X = Protected against ingress of solid objects Ø 1,0 mm and bigger – Use Rode Wire Probe Ø 1,0 mm

IP5X = Protected against dust/powder – e.g. – Use Dust Chamber Without Vacuum – Use Dust Chamber Tester

IP6X = Fully protected against dust/powder – e.g. – Use Dust Chamber With Vacuum 200 mmH20 – Use Dust Chamber Tester

Table. II – IP Code – Ingress Protection of Liquids

Short Description & IP Code Application Tips

0 = Not Protected

IPX1 = Protected against water drops – Use Drip Box Tester

IPX2 = Protected of a specimen in a position of tilt against water drops – Use Drip Box Tester & Turn Table

IPX3 = Protected Against Spraying of Water – Use Oscillating Tube Tester or Spray Nozzle

IPX4 = Protected Against Splashing Spray of Water – Use Oscillating tube Tester or Spray Nozzle

IPX5 = Protected Against Jet of Water – Use Jet Nozzle With IPX5 Tip

IPX6 = Protected Against Strong Jet of Water – Use Jet Nozzle With IPX6 Tip

IPX7 = Protected Against Timered Immersion – Use Immersion Tank

IPX8 = Protected Against Continued Immersion – Use Immersion tank IPX9K = Protected Against High Pressure and Temperature Water Jet Tester (this item will arrive soon at our inventory)