ANSI/UL 1598 sprinkler test apparatus for rain tests on wet-location luminaires, per ANSI/UL 1598 Fig. 19.18.1.
Standards
- ANSI/UL 1598 – cl. 19.18.1, Fig. 19.18.1 (wet-location luminaires)
- CSA C22.2 No. 250.0
- Also used for angled splash exposure: UL 50E / NEMA 250, CSA C22.2 No. 94.2, IEC 60598 series, IEC 60335 series
Technical data
| Nozzle | UL-type sprinkler nozzle, single |
| Orientation | 45° upward from floor level |
| Pressure range | 0–25 psi (0–172 kPa); typical 5 psi (34.5 kPa) |
| Gauge | Integrated, psi scale |
| Base | Floor-mounted aluminum frame |
| Materials | Corrosion-resistant |
| Certificate | ISO/IEC 17025 included |
Ref.: DNUL1598-1 (Dunel) / ORTYUL1598-1 (Ormity) – former codes: ORTY1598-19.18.1