DNTFI335  Dunel LIGHT INDICATOR 42VCA.jp

TEST PROBES

IEC ACCESSIBILITY TEST PROBES

render PB1_clipped_rev_2.png
jointed%20finger%20probe_edited.png
wire 1mm.png

HANDLED SPHERE PROBE - PROBE A

Project Subtitle

This probe is intended to verify the protection of persons against access to hazardous parts. It
is also used to verify the protection against access with the back of the hand.
Is related to Figure 1 – Test probe A of the IEC 61032 

JOINTED FINGER PROBE

Test probe B

Both joints shall permit movement in the same plane and the same direction through an angle of 90° with a 0°
to +10° tolerance.
This probe is intended to verify the basic protection against access to hazardous parts. It is also used to verify the protection against access with a finger.
Figure 2 – Test probe B of IEC 61032

2.5 MM WIRE PROBE

Test probe C

This rod is intended to verify the protection of persons against access to hazardous parts. It is also used to verify protection against access with a tool.
Test probe C of IEC 61032

wire probe 2.5.webp
ss sphere.jpg
ss12.5 mm.jpg

1 MM WIRE PROBE

Test probe D

This wire is intended to verify the protection of persons against access to hazardous parts. It is also used to verify the protection against access with a wire.
Figure 4 – Test probe D of IEC 61032

50 MM SPHERE PROBE

Test probe 1

This sphere is intended to verify the degree of protection of enclosures against ingress of solid foreign objects having a diameter of 50 mm or greater.
Figure 5 – Test probe 1 of iEC 61032

Contact

12.5 MM SPHERE PROBE

Probe 2

This sphere is intended to verify the degree of protection of enclosures against ingress of solid foreign objects having a diameter of 12,5 mm or greater.
Figure 6 – Test probe 2